Please read this document fully before applying the fix
1. Copy eqnkpr00.dll to the netfin directory.                   
                                                                        
2. There will a DCAF.INI file which is created in the netfin directory  
 the first time RWC is run, and used subsequently. This file has to be  
 deleted from the target system. This step is important, so make sure 
that this file doesn't exist in the target system before acessing it 
through RWC.     
                                                                        
3. The following line has to be added to the config.sys file.           
 SET RWCTIMER=1000                                                      
This is the environment variable from which the delay value is picked   
 up, This line is case sensitive so use all upper case letters. The     
 value can be anywhere from 300 to 10000. So for a high end machine (   
 with good CPU power & Display adapter) or when the resolution is low(  
 800 x 600 x 256), you can keep this value low. For a relatively low    
 end machine( P750 etc) you have to keep this value high. So you may    
 have to give a few tries for each kind of machine before getting the   
 correct result.                                                        
If the value entered is out of this range or if this variable is not    
 set the defalut value of 300 will be used.
Try from a lower value and increase it till it solves the problem.
                                                                        
4. Reboot the system & try to access it from another controlling        
 system.                                                                
                                                                        
5. If the response is not good, change the value in config.sys file,    
 delete the dcaf.ini file, reboot the system and try again.             
                                                                        
6. Once you have configured the value to your satisfaction, you don't   
 have to touch the dcaf.ini again.                                      
                                                                        
Notes:
1. The amount of delay required for scanning the whole RWC screen is       
 depending on the system configuration                                  
eg:- For a IBM PC300PL with PII CPU at  1024 x 768 x 16777216 at 60Hz   
 refresh rate , a delay of 1000 might be enough.                        
Where as for IBM PC 750 with PI 90 Mhz CPU at 800 x 600 x 16777216, 
a delay of 3000 msec might be necessary for RWC to work properly.                                                              

2. You should always try to keep the timer value to a minimum.   
3. In case you modify the timer value some time again in the future,   
 remember to delete dcaf.ini for the changes  to be effective. This is  
 because if DCAF.INI file doesn't exist it is created with the default  
 settings and this file is  used in all subsequent RWC operations. So   
 even if you change the value of RWCTIMER in config.sys at a later      
  date , it won't be used since the values are taken from the DCAF.INI