S Y M B O S   D E V E L O P E R   D O C U M E N T A T I O N
Author: Prodatron / Symbiosis
Date:   28.10.2005
===============================================================================

S Y S T E M   M A N A G E R

The system manager is responsible for starting and stopping applications and
for general system jobs. It provides several dialogue services and it owns the
file manager, which can only be accessed via the system manager process (for
more information see the "file manager" chapter).
System manager commands are triggered via a message, which has to be sent with
RST #10 (MSGSND) to the system manager process. The system manager process
always has the ID 3.


===============================================================================
SYSTEM MANAGER COMMANDS AND RESPONSES (APPLICATION MANAGEMENT)
-------------------------------------------------------------------------------
ID:             016 (MSC_SYS_PRGRUN)
Name:           Program_Run_Command
Library:        SySystem_PRGRUN
Message:        00  1B  016
                01  1W  File path and name address
                03  1B  [Bit0-3] File path and name ram bank (0-8)
                        [Bit7  ] Flag, if system error message should be
                                 suppressed
Description:    Loads and starts an application or opens a document with a
                known type by loading the associated application first.
                If Bit7 of P3 is not set, the system will open a message box,
                if an error occurs during the loading process.
Response:       See MSR_SYS_PRGRUN
-------------------------------------------------------------------------------
ID:             144 (MSR_SYS_PRGRUN)
Name:           Program_Run_Response
Message:        00  1B  144
                01  1B  Success status
                        0 = OK
                        1 = File does not exist
                        2 = File is not an executable and its type is not
                            associated with an application
                        3 = Error while loading (see P8 for error code)
                        4 = Memory full
                - If success status is 0:
                08  1B  Application ID
                09  1B  Process ID (the applications main process)
                - If success status is 3:
                08  1B  File manager error code
Description:    The system manager sends this message after trying to load an
                application or after opening an associated document. If the
                operation was successful, you will find the application ID and
                the process ID in P8 and P9. If it failed because of loading
                problems P8 contains the file manager error code.
-------------------------------------------------------------------------------
ID:             017 (MSC_SYS_PRGEND)
Name:           Program_End_Command
Library:        SySystem_PRGEND
Message:        00  1B  017
                01  1B  Application ID
Description:    Stops an application and releases all its used system
                resources. This command first stops all processes of the
                application. After this all open windows will be closed and the
                reserved memory will be released.
                Please note, that this command can't release memory, stop
                processes and timers or close windows, which are not registered
                for the application. Such resources first have to be released
                by the application itself.
Response:       [the system manager does not send a response message]
-------------------------------------------------------------------------------
ID:             020 (MSC_SYS_PRGSTA)
Name:           Program_Run_Dialogue_Command
Message:        00  1B  020
Description:    Opens the "run" dialogue. The user then can select an
                application or a document.
Response:       [the system manager does not send a response message]
-------------------------------------------------------------------------------
ID:             024 (MSC_SYS_PRGSET)
Name:           Program_Run_ControlPanel_Command
Message:        00  1B  024
                01  1B  Control panel sub module
                        0 = Main window
                        1 = Display settings
                        2 = time and date settings
Description:    Starts the control panel application or one of its two sub
                modules.
Response:       [the system manager does not send a response message]
-------------------------------------------------------------------------------
ID:             025 (MSC_SYS_PRGTSK)
Name:           Program_Run_TaskManager_Command
Message:        00  1B  025
Description:    Starts the task manager application.
Response:       [the system manager does not send a response message]
-------------------------------------------------------------------------------

===============================================================================
SYSTEM MANAGER COMMANDS (SYSTEM MANAGEMENT)

The system manager will not send response messages after processing the
following commands.
-------------------------------------------------------------------------------
ID:             018 (MSC_SYS_SYSWNX)
Name:           System_Dialogue_NextWindow_Command
Message:        00  1B  018
Description:    Opens the dialogue for changing the actual window. The next
                window is preselected.
                [THIS COMMAND IS NOT IMPLEMENTED YET]
-------------------------------------------------------------------------------
ID:             019 (MSC_SYS_SYSWPR)
Name:           System_Dialogue_PreviousWindow_Command
Message:        00  1B  019
Description:    Opens the dialogue for changing the actual window. The previous
                window is preselected.
                [THIS COMMAND IS NOT IMPLEMENTED YET]
-------------------------------------------------------------------------------
ID:             021 (MSC_SYS_SYSSEC)
Name:           System_Dialogue_SystemSecurity_Command
Message:        00  1B  021
Description:    Opens the "SymbOS security" dialogue.
-------------------------------------------------------------------------------
ID:             022 (MSC_SYS_SYSQIT)
Name:           System_Dialogue_ShutDown_Command
Message:        00  1B  022
Description:    Opens the "shut down" dialogue.
-------------------------------------------------------------------------------
ID:             023 (MSC_SYS_SYSOFF)
Name:           System_ShutDown_Command
Message:        00  1B  023
Description:    Resets the computer.
-------------------------------------------------------------------------------
ID:             028 (MSC_SYS_SYSCFG)
Name:           System_Configuration_Command
Message:        00  1B  028
                01  1B  Action type
                        0 = reload configuration
                        1 = save actual configuration
                        2 = reload or reinitialize desktop background picture
Description:    Loads or saves the configuration or reloads the desktop
                background picture or replaces it with an unique colour.
-------------------------------------------------------------------------------

===============================================================================
SYSTEM MANAGER COMMANDS AND RESPONSES (FILE MANAGEMENT)

The following command and response messages must be used for the communication
between the application and the file manager.
See the "file manager" chapter for more information about these messages.
-------------------------------------------------------------------------------
ID:             026 (MSC_SYS_SYSFIL)
Name:           System_Filemanager_Command
-------------------------------------------------------------------------------
ID:             154 (MSR_SYS_SYSFIL)
Name:           System_Filemanager_Response
-------------------------------------------------------------------------------

===============================================================================
SYSTEM MANAGER COMMANDS AND RESPONSES (DIALOGUE SERVICES)
-------------------------------------------------------------------------------
ID:             029 (MSC_SYS_SYSWRN)
Name:           Dialogue_Infobox_Command
Library:        SySystem_SYSWRN
Message:        00  1B  029
                01  1W  Content data address
                03  1B  Content data ram bank (0-8)
                04  1B  [Bit0-6] Number of buttons (MUST BY ALWAYS 1)
                        [Bit7  ] Box type
                                 0 = warning (default warning symbol)
                                 1 = info (own symbol will be used)
Content data:   00  1W  Address of text line 1
                02  1W  4 * [text line 1 pen] + 2
                04  1W  Address of text line 2
                06  1W  4 * [text line 2 pen] + 2
                08  1W  Address of text line 3
                10  1W  4 * [text line 3 pen] + 2
                - if P4[bit7] is 1:
                12  1W  Address of symbol (24x24 pixel SymbOS graphic format)
Description:    Opens an info or warning box and displays three line of text
                and one "OK" button. If Bit7 of P4 is set to 1 you can specify
                an own symbol, which will be showed left to the text. If this
                bit is not set, a "!"-warning symbol will be displayed.
                Currently multiple choice alert boxes are not supported, which
                means, that the number of buttons always have to be set to 1.
                Please note, that the content data must always be placed in the
                transfer ram area (#C000-#FFFF). The texts itself and the
                optional graphic must always be placed inside a 16K (data ram
                area).
                As the text line pen, you should choose 1, so 6 would be the
                correct value.
                For more information about the mentioned memory types (data,
                transfer) see the "applications" chapter.
                For more information about the SymbOS graphic format see the
                "desktop manager data records" chapter.
Response:       [the system manager does not send a response message]
-------------------------------------------------------------------------------
ID:             031 (MSC_SYS_SELOPN)
Name:           Dialogue_FileSelector_Command
Library:        SySystem_SELOPN
Message:        00  1B  031
                06  1B  File mask, path and name ram bank (0-8)
                07  1B  Attribute filter
                        Bit0 = 1 -> don't show read only files
                        Bit1 = 1 -> don't show hidden files
                        Bit2 = 1 -> don't show system files
                        Bit3 = 1 -> don't show volume ID entries
                        Bit4 = 1 -> don't show directories
                        Bit5 = 1 -> don't show archive files
                08  1W  File mask, path and name address (#C000-#FFFF)
                        00  3B  File extension filter (e.g. "*  ")
                        03  1B  0
                        04 256B path and filename
                10  1W  Maximum number of directory entries
                12  1W  Maximum size of directory data buffer
Description:    Opens the file selection dialogue. In this dialogue the user
                can move through the directory structure, change the drive and
                search and select a file.
                If you specify a path, the dialogue will start directly in the
                directory. If you append a filename, too, it will be used as
                the preselected file.
                You can filter the entries of the directory by attributes and
                filename extension. We recommend always to set Bit3 of the
                attribute filter byte.
                The File mask/path/name string (260 bytes) must always be
                placed in the transfer ram area (#C000-#FFFF). For more
                information about this memory types see the "applications"
                chapter.
                Please note, that the system will reserve memory to store the
                listed directory entries and the data structure of the list.
                With P10 and P12 you can choose, how much memory should be
                used. We recommend to set the number of entries between 100 and
                200 (Amsdos supports a maximum amount of 64 entries) and to set
                the data buffer between 5000 and 10000.
Response:       See MSR_SYS_SELOPN
-------------------------------------------------------------------------------
ID:             159 (MSR_SYS_SELOPN)
Name:           Dialogue_FileSelector_Response
Message:        00  1B  159
                01  1B  Message type
                         0 -> The user choosed a file and closed the dialogue
                              with "OK". The complete file path and name can be
                              found in the filepath buffer of the application.
                         1 -> The user aborted the file selection. The content
                              of the applications filepath buffer is unchanged.
                         2 -> The file selection dialogue is currently used by
                              another application. It can only be opened once
                              at the same time. The user should close the
                              dialogue first before it can be opened again by
                              the application.
                         3 -> Memory full. There was not enough memory
                              available for the directory buffer and/or the
                              list data structure.
                         4 -> No window available. The desktop manager couldn't
                              open a new window for the dialogue, as the
                              maximum number of windows (32) has already been
                              reached.
                        -1 -> The dialogue has been opened successful and the
                              user is doing his file selection right now.
                - if P1 is -1:
                02  1B  Number of the dialogue window + 1. The application
                        should store this number as the super window ID of its
                        own window, so that the file selection dialogue will be
                        handled as the super window of the application window.
                        As long as it is open the application window can't get
                        the focus position.
                        For more information about the window data structure
                        and super windows see the chapter "desktop manager".
Description:    The system manager sends back this message to the application,
                when a file selection dialogue should be opened.
                If opening was successful the application will first receive a
                type -1 message and then, after the user choosed his file or
                aborted, a type 0 or 1 message.
                If opening failed the application will directly receive a type
                2, 3 or 4 message.
-------------------------------------------------------------------------------

===============================================================================
SYSTEM MANAGER FUNCTIONS

The system manager functions have to be called with RST #28 (BNKFCL).
-------------------------------------------------------------------------------
Address:        #8103 (SYSINF)
Name:           System_Information
How to call:    ld hl,#8103:rst #28
Input:          E    = Request type
                       0 = get general information
                       1 = get application information
                       2 = get task information
                       3 = load mass storage device configuration
                       4 = save mass storage device configuration
                       5 = load a part of the configuration
                       6 = save a part of the configuration
                       7 = get config memory address
                       8 = get font and version string memory address
                D,IX,IY
                     = Sub specification
Output:         DE,IX,IY
                     = Data
Destroyed:      AF,BC,HL
Description:    This function is mainly used by the task manager and the
                control panel application. A detailed documentation may follow
                together with the internal data structure of processes and the
                system configuration.
-------------------------------------------------------------------------------