  ProLiant BL p-Class GbE2 Interconnect Switch Firmware, Version 1.0.1
---------------------------------------------------------------------------

- Usage information can be obtained from the following documentation:

    HP ProLiant BL p-Class GbE2 Interconnect Switch User Guide
    HP ProLiant BL p-Class GbE2 Interconnect Switch Application Guide
    HP ProLiant BL p-Class GbE2 Interconnect Switch Command Reference Guide
    HP ProLiant BL p-Class GbE2 Interconnect Switch Browser-based Interface
    Reference Guide 

  This documentation is downloadable from the Web at www.compaq.com/support

------------------------------------------------------------------------
  Known Issues:
------------------------------------------------------------------------


Issue: With some devices, when a GbE2 Interconnect Switch port is set to 100
Mbps speed with half-duplex (either with auto-negotiation on or auto-
negotiation off), link will never be established.

Suggestion: Do not set port speed to 100 half.



Issue: In the browser-based interface (BBI), the REVERT command on the main
banner does not work.

Suggestion: Use the REVERT button on the CONFIGURE mode screen or the GENERAL
screen instead. You can also use REVERT from the Command Line Interface 
(CLI).



Issue: When directly connected to the GbE2 Interconnect Switch front panel 
DB9 (console) port, the session will not timeout.

Suggestion: Exit from console when not in use.


Issue: When a Telnet connection is made from the GbE2 Interconnect Switch 
CLI to another device, characters are echoed making password fields visible.

Suggestion: If it is a security risk do not make a Telnet connection from 
the GbE2 Interconnect Switch.



Issue: If one switch is rebooted out of the pair in a blade enclosure, the 
other switch might report auto-negotiation errors on the console for ports 
not connected between these paired switches, even though there is no real 
problem.

Suggestion: Ignore these messages as erroneous.



Issue: Jumbo frames are forwarded correctly, but the statistics on the ports 
show them as 'oversized' frame errors.

Suggestion: The GbE2 Interconnect Switch firmware is counting Jumbo Frames 
as "oversized" frames and incrementing the Error counter. Ignore this counter 
when Jumbo Frames are used.  



Issue: The Browser Based Interface (BBI) does not offer support for all GbE2 
Interconnect Switch configuration settings and statistics monitoring. 

Suggestion: The preferred interface is the Command Line Interface (CLI).



Issue: Network links for servers running Linux occasionally will not 
establish link. 

Suggestion: Reload the NIC drivers on the Linux Blade server to get link to 
come up or reboot the server.  Refer to www.compaq.com/support for additional 
information.



Issue: Initiating a secure copy of the configuration file 
(scp <local_filename><switch IP addr>:putcfg_apply_save) from an external 
host server, the BOOTP assigned IP setting will be lost on the GbE2 
Interconnect Switch.

Suggestion: Do not use the scp command to transfer a configuration file 
to the switch. If this happens, disable and enable BOOTP to reestablish  
the IP settings.



Issue: Load distribution for multicast traffic is not supported over 
multi-link port trunks. For broadcast and multicast traffic, the lowest 
port number in the trunk group is elected to be the forwarding port for 
forwarding traffic.

Suggestion: No action is needed. 



Issue: Load distribution information for IP and non-IP traffic over 
multi-link port trunks is documented incorrectly in HP ProLiant BL 
p-Class GbE2 Interconnect Switch User Guide and the HP ProLiant BL 
p-Class GbE2 Interconnect Switch Application Guide.

- IP traffic on a trunk is forwarded on the port matching modulus 
(last_3_bits_of_Source_IP_address XOR last_3_bits_of_Destination
_IP_address).
 
- Non-IP traffic on a trunk is forwarded on the port  matching modulus 
(last_3_bits_of_Source_MAC_address XOR last_3_bits_of_Destination
_MAC_address).



Issue: Pings to a non-existing host IP address from the GbE2 Interconnect 
Switch CLI interface result in no response for random periods of time.

Suggestion: Wait a short while for response to resume.


Issue: The BBI REVERT option fails to correctly undo VLAN creation.

Suggestion: Use the CLI to create VLANs.



Issue: CPU utilization is incorrect.

Suggestion: Ignore the reported CPU utilization.



Issue: The BBI does not time out after inactivity.

Suggestion: Logout when you are finished with the BBI.



Issue:  Firmware or boot image upgrades via TFTP on slower connections
(e.g. 33.6 kb/sec) that require over 11 minutes to complete may fail.

Suggestion:  Use a faster connection to perform upgrades.



Issue: Broadcast/Multicast Small/Oversized/Jumbo frames are incorrectly 
identified as Unicast in the statistics.

Suggestion: Ignore these statistics.

----------------------------------------------------------------------------

Hewlett-Packard Company shall not be liable for technical or editorial errors
or omissions contained herein. The information in this document is provided 
"as is" without warranty of any kind and is subject to change without notice.
The warranties for HP products are set forth in the express limited warranty 
statements accompanying such products. Nothing herein should be construed as 
constituting an additional warranty.


(c) 2002, 2003 Hewlett-Packard Development Company, L.P.