Final Release of Patch V86L-4

Only applicable to V86L-1 Code Build Stream
Pre-requisite patches  V86L-2, and -3  must be installed prior to this 
patch.

*************** COMPAQ COMPUTER CORPORATION  DISCLAIMER **************
* In accordance to Compaq's commitment to maintain the highest level  *
* of customer satisfaction, this patch is being provided to customers *
* who have purchased the referenced Storageworks product that is      *
* currently covered by one of Compaq's  extensive warranty plans and  *
* is also provided to those customers not yet underCompaq's extended  *
* warranty plan as a courtesy.  The availability of this patch is in  *
* no way an obligation by Compaq to continue this practice in the     *
* future.                                                             *
***********************************************************************

****************************** WARNING ********************************
*                                                                     *
* - Please be sure to cut and paste EXACTLY as indicated.  Any        *
*   addition or subtraction of pertinent patch data will mean the     *
*   patch will not load due to a checksum failure and the controller  *
*   will remain at it's original version.                             *
*                                                                     *
* - As always, any critical data should be backed up prior to         * 
*   performing any updates.                                           *
***********************************************************************

				PATCH V86L-4

Patch Title:    Evict Devices for Hardware Errors 
HSOF Version:   HSG60 V86
Patch Number:   4	
Date:           14-DEC-2001

I.     Patch Description:

   Problem Symptoms:  
     1.  Disk drive had hardware error reported via check condition with
         Sense_Key=4.  This occurrence led controller through Bus Reset  
         as recovery.  Under load conditions this could propogated to 
         several failure scenerios, including controller crashes 
         with PCI Faults, i960, deadman timer. 

   Resolution: 
     1.  At lowest level possible, we capture hardware errors as 
         reported by disk devices, and immediately throw the device into
         the failedset.  Devices thrown into Failedset should be 
         considered defective and replaced. 

Title:  Evict Devices for Hardware Errors

Version:        V86L
Length:         84
Patch Type:     0
Patch Number:   4

 Count:         16
 Address:       C00D1810
 Value[  0]:    5CA01E04
 Value[  1]:    92A12104
 Value[  2]:    5CA81E02
 Value[  3]:    90A120F4
 Value[  4]:    82A920F3
 Value[  5]:    90A9206C
 Value[  6]:    58A50997
 Value[  7]:    92A120F4
 Value[  8]:    5CA01E02
 Value[  9]:    92A560C0
 Value[ 10]:    9081206C
 Value[ 11]:    5C881E10
 Value[ 12]:    86003000
 Value[ 13]:    C00BB2F0
 Value[ 14]:    84003000
 Value[ 15]:    C00D1954

 Count:         0

Verification:   32D6D191


II.    Patch Installation Script for use with a host to CLI Utility 


Extract the following script to file PATCH_V86L-4.script. 
Submit script to CCL via Command Scripter utility.

----- Begin Script -----
!
!Evict Devices for Hardware Errors
!
run clcp
2
1
y
V86L
84
0
4
16
C00D1810
5CA01E04
92A12104
5CA81E02
90A120F4
82A920F3
90A9206C
58A50997
92A120F4
5CA01E02
92A560C0
9081206C
5C881E10
86003000
C00BB2F0
84003000
C00D1954
0
32D6D191
3
0
----- End Script -----




III.   Patch file for use with SWCC Client's Update Software feature. 

Extract the following to filename PATCH_V86L-4_INSTALL.WB_DATA and 
transfer to the Client host.  Specify it in the 'File to load' box 
from the SWCC Update Controller Software screen as selected via the 
'Storage' menu option.


----- Begin SWCC Script -----
! Evict Devices for Hardware Errors install (c) COMPAQ 12-DEC-2001 !
1
V86L
84
0
4
16
C00D1810
5CA01E04
92A12104
5CA81E02
90A120F4
82A920F3
90A9206C
58A50997
92A120F4
5CA01E02
92A560C0
9081206C
5C881E10
86003000
C00BB2F0
84003000
C00D1954
0
32D6D191
----- End SWCC Script -----


IV.   Patch Deletion Script for use with SWCC Client'S Update feature. 

Extract the following to filename to PATCH_V86L-4_DELETE.WB_DATA and 
transfer to the Client host.  Specify it in the 'File to load' box from
the SWCC Update Controller Software screen as selected via the
'Storage' menu option.

----- Begin Script -----
! Evict Devices for Hardware Errors delete (c) COMPAQ 12-DEC-2001 !
2
V86L
4
----- End Script -----