#* **************************************************************************
#*
#*                  Insight Integration for CA Unicenter
#*
#*      Copyright 1996,2003 Hewlett-Packard Development Company, L.P.
#*
#*      Hewlett-Packard Company shall not be liable for technical or
#*      editorial errors or omissions contained herein. The information in
#*      this document is provided "as is" without warranty of any kind and
#*      is subject to change without notice. The warranties for HP products
#*      are set forth in the express limited warranty statements
#*      accompanying such products. Nothing herein should be construed as
#*      constituting an additional warranty.
#*
#*      Confidential computer software. Valid license from HP required for
#*      possession, use or copying. Consistent with FAR 12.211 and 12.212,
#*      Commercial Computer Software, Computer Software Documentation, and
#*      Technical Data for Commercial Items are licensed to the U.S.
#*      Government under vendor's standard commercial license.
#*
#* **************************************************************************
#*                                                                        
#* PROPRIETARY NOTE:                                                      
#*     This document contains information confidential and proprietary to 
#*     Hewlett-Packard and shall not be reproduced or transferred to other
#*     documents or disclosed to others or used for any purpose other than 
#*     that for which it was obtained without the expressed written consent
#*     of Hewlett-Packard Company.
#*                                                                        
#* **************************************************************************


#-------------------------------------------------
#
# SCSI Trap 5018 - Tape Library Status Change
#
#-------------------------------------------------

DEFine MSGREcord MSGID='* SNMPTRAP: * * *232 * * 6 5018*'
       MSGNODE=*
       DEScription='HP - Tape Library Status Change (5018)'
       TYPE=MSG
DEFine MSGACTion NAME=(*,10)
       ACTION=sendkeep TEXT='HP - Tape Library Status Change. (Controller: &26, Bus: &31, SCSI ID: &36, LUN: &41, Variables: &(46:))'
       SEVERITY=E
       ATTRIB=default
       COLOR=red
DEFine MSGACTion Name=(*,20)
       ACTION=ANNOTATE TEXT='The trap variables were sent in the alarm, but they could not be properly parsed for information.  The variable information is displayed as part of the message.'

DEFine MSGREcord MSGID='* SNMPTRAP: * * *232 * * 6 5018 * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * 1*'
       MSGNODE=*
       DEScription='HP - Tape Library Status Change (5018): OTHER'
       TYPE=MSG
DEFine MSGACTion NAME=(*,10)
       ACTION=sendkeep TEXT='HP - Tape Library Status OTHER (Controller: &26, Bus: &31, SCSI ID: &36, LUN: &41, Library Name: &(46:49), FW Rev: &54, SN: &59)'
       SEVERITY=I
       ATTRIB=default
       COLOR=blue

DEFine MSGREcord MSGID='* SNMPTRAP: * * *232 * * 6 5018 * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * 2*'
       MSGNODE=*
       DEScription='HP - Tape Library Status Change (5018): OK'
       TYPE=MSG
DEFine MSGACTion NAME=(*,10)
       ACTION=sendkeep TEXT='HP - Tape Library Status OK (Controller: &26, Bus: &31, SCSI ID: &36, LUN: &41, Library Name: &(46:49), FW Rev: &54, SN: &59)'
       SEVERITY=S
       ATTRIB=default
       COLOR=green

DEFine MSGREcord MSGID='* SNMPTRAP: * * *232 * * 6 5018 * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * 3*'
       MSGNODE=*
       DEScription='HP - Tape Library Status Change (5018): DEGRADED'
       TYPE=MSG
DEFine MSGACTion NAME=(*,10)
       ACTION=sendkeep TEXT='HP - Tape Library Status DEGRADED (Controller: &26, Bus: &31, SCSI ID: &36, LUN: &41, Library Name: &(46:49), FW Rev: &54, SN: &59)'
       SEVERITY=I
       ATTRIB=default
       COLOR=blue

DEFine MSGREcord MSGID='* SNMPTRAP: * * *232 * * 6 5018 * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * 4*'
       MSGNODE=*
       DEScription='HP - Tape Library Status Change (5018): FAILED'
       TYPE=MSG
DEFine MSGACTion NAME=(*,10)
       ACTION=sendkeep TEXT='HP - Tape Library Status FAILED (Controller: &26, Bus: &31, SCSI ID: &36, LUN: &41, Library Name: &(46:49), FW Rev: &54, SN: &59)'
       SEVERITY=E
       ATTRIB=default
       COLOR=red

DEFine MSGREcord MSGID='* SNMPTRAP: * * *232 * * 6 5018 * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * 5*'
       MSGNODE=*
       DEScription='HP - Tape Library Status Change (5018): OFFLINE'
       TYPE=MSG
DEFine MSGACTion NAME=(*,10)
       ACTION=sendkeep TEXT='HP - Tape Library Status OFFLINE (Controller: &26, Bus: &31, SCSI ID: &36, LUN: &41, Library Name: &(46:49), FW Rev: &54, SN: &59)'
       SEVERITY=I
       ATTRIB=default
       COLOR=blue
DEFine MSGACTion NAME=(*,20)
       ACTION=ANNOTATE TEXT='Indicates that the Insight Agents can no longer communicate with the library.  This could be caused by a cabling problem or the library may be powered off.'

#----------------------------------------------------------------------------------------
# Trap definitions for 5018 are repeated here for library systems that don't send a 
#  serial number
#

DEFine MSGREcord MSGID='* SNMPTRAP: * * *232 * * 6 5018 * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * 1*'
       MSGNODE=*
       DEScription='HP - Tape Library Status Change (5018): OTHER'
       TYPE=MSG
DEFine MSGACTion NAME=(*,10)
       ACTION=sendkeep TEXT='HP - Tape Library Status OTHER (Controller: &26, Bus: &31, SCSI ID: &36, LUN: &41, Library Name: &(46:49), FW Rev: &54)'
       SEVERITY=I
       ATTRIB=default
       COLOR=blue

DEFine MSGREcord MSGID='* SNMPTRAP: * * *232 * * 6 5018 * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * 2*'
       MSGNODE=*
       DEScription='HP - Tape Library Status Change (5018): OK'
       TYPE=MSG
DEFine MSGACTion NAME=(*,10)
       ACTION=sendkeep TEXT='HP - Tape Library Status OK (Controller: &26, Bus: &31, SCSI ID: &36, LUN: &41, Library Name: &(46:49), FW Rev: &54)'
       SEVERITY=S
       ATTRIB=default
       COLOR=green


DEFine MSGREcord MSGID='* SNMPTRAP: * * *232 * * 6 5018 * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * 3*'
       MSGNODE=*
       DEScription='HP - Tape Library Status Change (5018): DEGRADED'
       TYPE=MSG
DEFine MSGACTion NAME=(*,10)
       ACTION=sendkeep TEXT='HP - Tape Library Status DEGRADED (Controller: &26, Bus: &31, SCSI ID: &36, LUN: &41, Library Name: &(46:49), FW Rev: &54)'
       SEVERITY=I
       ATTRIB=default
       COLOR=blue

DEFine MSGREcord MSGID='* SNMPTRAP: * * *232 * * 6 5018 * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * 4*'
       MSGNODE=*
       DEScription='HP - Tape Library Status Change (5018): FAILED'
       TYPE=MSG
DEFine MSGACTion NAME=(*,10)
       ACTION=sendkeep TEXT='HP - Tape Library Status FAILED (Controller: &26, Bus: &31, SCSI ID: &36, LUN: &41, Library Name: &(46:49), FW Rev: &54)'
       SEVERITY=E
       ATTRIB=default
       COLOR=red

DEFine MSGREcord MSGID='* SNMPTRAP: * * *232 * * 6 5018 * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * 5*'
       MSGNODE=*
       DEScription='HP - Tape Library Status Change (5018): OFFLINE'
       TYPE=MSG
DEFine MSGACTion NAME=(*,10)
       ACTION=sendkeep TEXT='HP - Tape Library Status OFFLINE (Controller: &26, Bus: &31, SCSI ID: &36, LUN: &41, Library Name: &(46:49), FW Rev: &54)'
       SEVERITY=I
       ATTRIB=default
       COLOR=blue
DEFine MSGACTion NAME=(*,20)
       ACTION=ANNOTATE TEXT='Indicates that the Insight Agents can no longer communicate with the library.  This could be caused by a cabling problem or the library may be powered off.'

#---------------------------------------------------------------------------------------------

#----------------------------------------------
#
# SCSI Trap 5019 - Tape Drive Status Change
#
#----------------------------------------------

DEFine MSGREcord MSGID='* SNMPTRAP: * * *232 * * 6 5019*'
       MSGNODE=*
       DEScription='HP - Tape Drive Status Change (5019)'
       TYPE=MSG
DEFine MSGACTion NAME=(*,10)
       ACTION=sendkeep TEXT='HP - Tape Drive Status Change. (Controller: &26, Bus: &31, SCSI ID: &36, LUN: &41, Variables: &(46:))'
       SEVERITY=E
       ATTRIB=default
       COLOR=red
DEFine MSGACTion Name=(*,20)
       ACTION=ANNOTATE TEXT='The trap variables were sent in the alarm, but they could not be properly parsed for information.  The variable information is displayed as part of the message.'
DEFine MSGACTion Name=(*,30)
       ACTION=ANNOTATE TEXT='The last variable displayed in the list is the status variable (displayed as VALUE: STATUS where status can be other(1), ok(2), failed(4), offline(5), missingWasOk(6), missingWasFailed(7), or missingWasOffline(8)).'


DEFine MSGREcord MSGID='* SNMPTRAP: * * *232 * * 6 5019 * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * 1*'
       MSGNODE=*
       DEScription='HP - Tape Drive Status Change (5019): OTHER'
       TYPE=MSG
DEFine MSGACTion NAME=(*,10)
       ACTION=sendkeep TEXT='HP - Tape Drive Status OTHER (Controller: &26, Bus: &31, SCSI ID: &36, LUN: &41, Drive Name: &(46:49), FW Rev: &54, SN: &59)'
       SEVERITY=I
       ATTRIB=default
       COLOR=blue

DEFine MSGREcord MSGID='* SNMPTRAP: * * *232 * * 6 5019 * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * 2*'
       MSGNODE=*
       DEScription='HP - Tape Drive Status Change (5019): OK'
       TYPE=MSG
DEFine MSGACTion NAME=(*,10)
       ACTION=sendkeep TEXT='HP - Tape Drive Status OK (Controller: &26, Bus: &31, SCSI ID: &36, LUN: &41, Drive Name: &(46:49), FW Rev: &54, SN: &59)'
       SEVERITY=S
       ATTRIB=default
       COLOR=green

DEFine MSGREcord MSGID='* SNMPTRAP: * * *232 * * 6 5019 * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * 4*'
       MSGNODE=*
       DEScription='HP - Tape Drive Status Change (5019): FAILED'
       TYPE=MSG
DEFine MSGACTion NAME=(*,10)
       ACTION=sendkeep TEXT='HP - Tape Drive Status FAILED (Controller: &26, Bus: &31, SCSI ID: &36, LUN: &41, Drive Name: &(46:49), FW Rev: &54, SN: &59)'
       SEVERITY=E
       ATTRIB=default
       COLOR=red


DEFine MSGREcord MSGID='* SNMPTRAP: * * *232 * * 6 5019 * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * 5*'
       MSGNODE=*
       DEScription='HP - Tape Drive Status Change (5019): OFFLINE'
       TYPE=MSG
DEFine MSGACTion NAME=(*,10)
       ACTION=sendkeep TEXT='HP - Tape Drive Status OFFLINE (Controller: &26, Bus: &31, SCSI ID: &36, LUN: &41, Drive Name: &(46:49), FW Rev: &54, SN: &59)'
       SEVERITY=I
       ATTRIB=default
       COLOR=blue
DEFine MSGACTion NAME=(*,20)
       ACTION=ANNOTATE TEXT='Offline - Indicates that the tape physical drive is offline and can no longer return data.  No further status is available.'


DEFine MSGREcord MSGID='* SNMPTRAP: * * *232 * * 6 5019 * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * 6*'
       MSGNODE=*
       DEScription='HP - Tape Drive Status Change (5019): MISSING WAS OK'
       TYPE=MSG
DEFine MSGACTion NAME=(*,10)
       ACTION=sendkeep TEXT='HP - Tape Drive Status MissingWasOk (Controller: &26, Bus: &31, SCSI ID: &36, LUN: &41, Drive Name: &(46:49), FW Rev: &54, SN: &59)'
       SEVERITY=E
       ATTRIB=default
       COLOR=red
DEFine MSGACTion NAME=(*,20)
       ACTION=ANNOTATE TEXT='Missing Was Ok - Indicates that a tape physical drive had a status of OK and is no longer present.  The drive has been removed.'


DEFine MSGREcord MSGID='* SNMPTRAP: * * *232 * * 6 5019 * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * 7*'
       MSGNODE=*
       DEScription='HP - Tape Drive Status Change (5019): MISSING WAS FAILED'
       TYPE=MSG
DEFine MSGACTion NAME=(*,10)
       ACTION=sendkeep TEXT='HP - Tape Drive Status MissingWasFailed (Controller: &26, Bus: &31, SCSI ID: &36, LUN: &41, Drive Name: &(46:49), FW Rev: &54, SN: &59)'
       SEVERITY=E
       ATTRIB=default
       COLOR=red
DEFine MSGACTion NAME=(*,20)
       ACTION=ANNOTATE TEXT='Missing Was Failed - Indicates that a tape physical drive had a status of FAILED and is no longer present.  The drive has been removed.'


DEFine MSGREcord MSGID='* SNMPTRAP: * * *232 * * 6 5019 * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * 8*'
       MSGNODE=*
       DEScription='HP - Tape Drive Status Change (5019): MISSING WAS OFFLINE'
       TYPE=MSG
DEFine MSGACTion NAME=(*,10)
       ACTION=sendkeep TEXT='HP - Tape Drive Status MissingWasOffline (Controller: &26, Bus: &31, SCSI ID: &36, LUN: &41, Drive Name: &(46:49), FW Rev: &54, SN: &59)'
       SEVERITY=E
       ATTRIB=default
       COLOR=red
DEFine MSGACTion NAME=(*,20)
       ACTION=ANNOTATE TEXT='Missing Was Offline - Indicates that a tape physical drive had a status of OFFLINE and is no longer present.  The drive has been removed.'




#
# SCSI Trap 5020 - Physical Drive Status Change
#


DEFine MSGREcord MSGID='* SNMPTRAP: * * *232 * * 6 5020 * * * * * * * * * * * * * * * * 1*'
       MSGNODE=*
       DEScription='HP - SCSI Physical Drive Status Change (5020): OTHER'
       TYPE=MSG
DEFine MSGACTion NAME=(*,10)
       ACTION=sendkeep TEXT='HP - SCSI Physical Drive Status OTHER (Controller: &31, Bus: &36, Drive: &41, Vendor: &46, Model: &51, Firmware: &56, S/N: &61, OS Name: &66 &67)'
       SEVERITY=I
       ATTRIB=default
       COLOR=blue


DEFine MSGREcord MSGID='* SNMPTRAP: * * *232 * * 6 5020 * * * * * * * * * * * * * * * * 2*'
       MSGNODE=*
       DEScription='HP - SCSI Physical Drive Status Change (5020): OK'
       TYPE=MSG
DEFine MSGACTion NAME=(*,10)
       ACTION=sendkeep TEXT='HP - SCSI Physical Drive Status OK (Controller: &31, Bus: &36, Drive: &41, Vendor: &46, Model: &51, Firmware: &56, S/N: &61, OS Name: &66 &67)'
       SEVERITY=S
       ATTRIB=default
       COLOR=green


DEFine MSGREcord MSGID='* SNMPTRAP: * * *232 * * 6 5020 * * * * * * * * * * * * * * * * 3*'
       MSGNODE=*
       DEScription='HP - SCSI Physical Drive Status Change (5020): FAILED'
       TYPE=MSG
DEFine MSGACTion NAME=(*,10)
       ACTION=sendkeep TEXT='HP - SCSI Physical Drive Status FAILED (Controller: &31, Bus: &36, Drive: &41, Vendor: &46, Model: &51, Firmware: &56, S/N: &61, OS Name: &66 &67)'
       SEVERITY=E
       ATTRIB=default
       COLOR=red
DEFine MSGACTion NAME=(*,20)
       ACTION=ANNOTATE TEXT='Indicates that the physical drive has failed and can no longer return data.  When convenient, you should bring down the server and run diagnostics to help identify the problem. The drive may need to be replaced.'


DEFine MSGREcord MSGID='* SNMPTRAP: * * *232 * * 6 5020 * * * * * * * * * * * * * * * * 4*'
       MSGNODE=*
       DEScription='HP - SCSI Physical Drive Status Change (5020): NOT CONFIGURED'
       TYPE=MSG
DEFine MSGACTion NAME=(*,10)
       ACTION=sendkeep TEXT='HP - SCSI Physical Drive Status NotConfigured (Controller: &31, Bus: &36, Drive: &41, Vendor: &46, Model: &51 &52, Firmware: &57, S/N: &62, OS Name: &67)'
       SEVERITY=I
       ATTRIB=default
       COLOR=blue
DEFine MSGACTion NAME=(*,20)
       ACTION=ANNOTATE TEXT='Indicates that the physical drive is not configured.  You need to insure all of the drive switches are properly set and that the Configuration Utility has been run.'


DEFine MSGREcord MSGID='* SNMPTRAP: * * *232 * * 6 5020 * * * * * * * * * * * * * * * * 5*'
       MSGNODE=*
       DEScription='HP - SCSI Physical Drive Status Change (5020): BAD CABLE'
       TYPE=MSG
DEFine MSGACTion NAME=(*,10)
       ACTION=sendkeep TEXT='HP - SCSI Physical Drive Status BadCable (Controller: &31, Bus: &36, Drive: &41, Vendor: &46, Model: &51, Firmware: &56, S/N: &61, OS Name: &66 &67)'
       SEVERITY=W
       ATTRIB=default
       COLOR=orange
DEFine MSGACTion NAME=(*,20)
       ACTION=ANNOTATE TEXT='Indicates that a physical drive is not responding. You should check the cables connected to it.  You can bring down the server and run diagnostics to help identify the problem.'


DEFine MSGREcord MSGID='* SNMPTRAP: * * *232 * * 6 5020 * * * * * * * * * * * * * * * * 6*'
       MSGNODE=*
       DEScription='HP - SCSI Physical Drive Status Change (5020): MISSING WAS OK'
       TYPE=MSG
DEFine MSGACTion NAME=(*,10)
       ACTION=sendkeep TEXT='HP - SCSI Physical Drive Status MissingWasOk (Controller: &31, Bus: &36, Drive: &41, Vendor: &46, Model: &51, Firmware: &56, S/N: &61, OS Name: &66 &67)'
       SEVERITY=E
       ATTRIB=default
       COLOR=red
DEFine MSGACTion NAME=(*,20)
       ACTION=ANNOTATE TEXT='Indicates that a physical drive had a status of OK and is no longer present.  The drive has been removed.'


DEFine MSGREcord MSGID='* SNMPTRAP: * * *232 * * 6 5020 * * * * * * * * * * * * * * * * 7*'
       MSGNODE=*
       DEScription='HP - SCSI Physical Drive Status Change (5020): MISSING WAS FAILED'
       TYPE=MSG
DEFine MSGACTion NAME=(*,10)
       ACTION=sendkeep TEXT='HP - SCSI Physical Drive Status MissingWasFailed (Controller: &31, Bus: &36, Drive: &41, Vendor: &46, Model: &51, Firmware: &56, S/N: &61, OS Name: &66 &67)'
       SEVERITY=E
       ATTRIB=default
       COLOR=red
DEFine MSGACTion NAME=(*,20)
       ACTION=ANNOTATE TEXT='Indicates that a physical drive had a status of FAILED and is no longer present.  The drive has been removed.'


DEFine MSGREcord MSGID='* SNMPTRAP: * * *232 * * 6 5020 * * * * * * * * * * * * * * * * 8*'
       MSGNODE=*
       DEScription='HP - SCSI Physical Drive Status Change (5020): PREDICTIVE FAILURE'
       TYPE=MSG
DEFine MSGACTion NAME=(*,10)
       ACTION=sendkeep TEXT='HP - SCSI Physical Drive Status PredictiveFailure (Controller: &31, Bus: &36, Drive: &41, Vendor: &46, Model: &51, Firmware: &56, S/N: &61, OS Name: &66 &67)'
       SEVERITY=W
       ATTRIB=default
       COLOR=orange
DEFine MSGACTion NAME=(*,20)
       ACTION=ANNOTATE TEXT='Indicates that the physical drive has exceeded a threshold value for one of the predictive indicators. When convenient, you should bring down the server and run diagnostics to help identify the problem. The drive may need to be replaced.'


DEFine MSGREcord MSGID='* SNMPTRAP: * * *232 * * 6 5020 * * * * * * * * * * * * * * * * 9*'
       MSGNODE=*
       DEScription='HP - SCSI Physical Drive Status Change (5020): MISSING WAS PREDICTIVE FAILURE'
       TYPE=MSG
DEFine MSGACTion NAME=(*,10)
       ACTION=sendkeep TEXT='HP - SCSI Physical Drive Status MissingWasPredictiveFailure (Controller: &31, Bus: &36, Drive: &41, Vendor: &46, Model: &51, Firmware: &56, S/N: &61, OS Name: &66 &67)'
       SEVERITY=E
       ATTRIB=default
       COLOR=red
DEFine MSGACTion NAME=(*,20)
       ACTION=ANNOTATE TEXT='Indicates that a physical drive had a status of PREDICTIVE FAILURE and is no longer present.  The drive has been removed.'

DEFine MSGREcord MSGID='* SNMPTRAP: * * *232 * * 6 5020 * * * * * * * * * * * * * * * * 10*'
       MSGNODE=*
       DEScription='HP - SCSI Physical Drive Status Change (5020): OFFLINE'
       TYPE=MSG
DEFine MSGACTion NAME=(*,10)
       ACTION=sendkeep TEXT='HP - SCSI Physical Drive Status Offline (Controller: &31, Bus: &36, Drive: &41, Vendor: &46, Model: &51, Firmware: &56, S/N: &61, OS Name: &66 &67)'
       SEVERITY=I
       ATTRIB=default
       COLOR=blue
DEFine MSGACTion NAME=(*,20)
       ACTION=ANNOTATE TEXT='Indicates that the physical drive is offline and can no longer return data.  No further status is available.'


DEFine MSGREcord MSGID='* SNMPTRAP: * * *232 * * 6 5020 * * * * * * * * * * * * * * * * 11*'
       MSGNODE=*
       DEScription='HP - SCSI Physical Drive Status Change (5020): MISSING WAS OFFLINE'
       TYPE=MSG
DEFine MSGACTion NAME=(*,10)
       ACTION=sendkeep TEXT='HP - SCSI Physical Drive Status MissingWasOffline (Controller: &31, Bus: &36, Drive: &41, Vendor: &46, Model: &51, Firmware: &56, S/N: &61, OS Name: &66 &67)'
       SEVERITY=E
       ATTRIB=default
       COLOR=red
DEFine MSGACTion NAME=(*,20)
       ACTION=ANNOTATE TEXT='Indicates that a physical drive had a status of OFFLINE and is no longer present.  The drive has been removed.'


DEFine MSGREcord MSGID='* SNMPTRAP: * * *232 * * 6 5020 * * * * * * * * * * * * * * * * 12*'
       MSGNODE=*
       DEScription='HP - SCSI Physical Drive Status Change (5020): HARD ERROR'
       TYPE=MSG
DEFine MSGACTion NAME=(*,10)
       ACTION=sendkeep TEXT='HP - SCSI Physical Drive Status HardError (Controller: &31, Bus: &36, Drive: &41, Vendor: &46, Model: &51, Firmware: &56, S/N: &61, OS Name: &66 &67)'
       SEVERITY=E
       ATTRIB=default
       COLOR=red
DEFine MSGACTion NAME=(*,20)
       ACTION=ANNOTATE TEXT='Indicates that a hard error occurred for this physical drive.'

