#*                  Insight Integration for CA Unicenter
#*
#*      Copyright 1996,2003 Hewlett-Packard Development Company, L.P.
#*
#*      Hewlett-Packard Company shall not be liable for technical or
#*      editorial errors or omissions contained herein. The information in
#*      this document is provided "as is" without warranty of any kind and
#*      is subject to change without notice. The warranties for HP products
#*      are set forth in the express limited warranty statements
#*      accompanying such products. Nothing herein should be construed as
#*      constituting an additional warranty.
#*
#*      Confidential computer software. Valid license from HP required for
#*      possession, use or copying. Consistent with FAR 12.211 and 12.212,
#*      Commercial Computer Software, Computer Software Documentation, and
#*      Technical Data for Commercial Items are licensed to the U.S.
#*      Government under vendor's standard commercial license.
#*
#* **************************************************************************
#*                                                                        
#* PROPRIETARY NOTE:                                                      
#*     This document contains information confidential and proprietary to 
#*     Hewlett-Packard and shall not be reproduced or transferred to other
#*     documents or disclosed to others or used for any purpose other than 
#*     that for which it was obtained without the expressed written consent
#*     of Hewlett-Packard Company.
#*                                                                        
#* **************************************************************************

DEFine MSGREcord MSGID='* SNMPTRAP: * * *232 * * 6 2001 *'
       MSGNODE=*
       DEScription='HP - Desktop Hood Alert'
       TYPE=MSG
DEFine MSGACTion NAME=(*,10)
       ACTION=sendkeep TEXT='HP - Desktop Hood Removed From Unit'
       SEVerity=I
       ATTRIB=default
       COLOR=blue
DEFine MSGACTion NAME=(*,20)
       ACTION=ANNOTATE TEXT='The system hood is not in a properly installed state or the hood has been removed since the last time the system was powered on. This situation may result in improper cooling of the system due to air flow changes caused by the missing hood.'


DEFine MSGREcord MSGID='* SNMPTRAP: * * *232 * * 6 2002 *'
       MSGNODE=*
       DEScription='HP - Desktop Monitor OK'
       TYPE=MSG
DEFine MSGACTion NAME=(*,10)
       ACTION=sendkeep TEXT='HP - Desktop Monitor Condition OK'
       SEVerity=S
       ATTRIB=default
       COLOR=green
DEFine MSGACTion NAME=(*,20)
       ACTION=ANNOTATE TEXT='Fault reporting features have returned to within their normal operating range for the monitor. The monitors condition has been set to OK.'

DEFine MSGREcord MSGID='* SNMPTRAP: * * *232 * * 6 2003 *'
       MSGNODE=*
       DEScription='HP - Desktop Monitor Condition DEGRADED'
       TYPE=MSG
DEFine MSGACTion NAME=(*,10)
       ACTION=sendkeep TEXT='HP - Desktop Monitor Condition DEGRADED'
       SEVerity=W
       ATTRIB=default
       COLOR=orange
DEFine MSGACTion NAME=(*,20)
       ACTION=ANNOTATE TEXT='A fault reporting feature has exceeded normal limits for the monitor. The monitors condition is degraded due to the internal temperature exceeding normal operating limits.'
DEFine MSGACTion NAME=(*,30)
       ACTION=ANNOTATE TEXT='The monitor is still useable, but action should be taken to return the condition to OK.'
DEFine MSGACTion NAME=(*,40)
       ACTION=ANNOTATE TEXT='Follow these steps: Physically check for obstructions to air flow around the monitor, Check the thermostat in the room that the system occupies, Allow the monitor to cool by turning off the monitor for 5 minutes then turn the monitor back on.'

DEFine MSGREcord MSGID='* SNMPTRAP: * * *232 * * 6 2004 *'
       MSGNODE=*
       DEScription='HP - Desktop Monitor: FAILED'
       TYPE=MSG
DEFine MSGACTion NAME=(*,10)
       ACTION=sendkeep TEXT='HP - Desktop Monitor Condition FAILED'
       SEVerity=E
       ATTRIB=default
       COLOR=red
DEFine MSGACTion NAME=(*,20)
       ACTION=ANNOTATE TEXT='A fault reporting feature has exceeded normal limits in the monitor. The monitors condition has been set to failed due to an operational feature exceeding normal operating limits. The monitor will not be useable and should be replaced.'

DEFine MSGREcord MSGID='* SNMPTRAP: * * *232 * * 6 2005 *'
       MSGNODE=*
       DEScription='HP - Desktop Correctable Memory: DEGRADED'
       TYPE=MSG
DEFine MSGACTion NAME=(*,10)
       ACTION=sendkeep TEXT='HP - Desktop Correctable Memory: DEGRADED'
       SEVerity=W
       ATTRIB=default
       COLOR=orange
DEFine MSGACTion NAME=(*,20)
       ACTION=ANNOTATE TEXT='Correctable memory error count has exceeded the threshold for the memory module. The appropriate Memory Module ECC Status has been set to degraded.'
DEFine MSGACTion NAME=(*,30)
       ACTION=ANNOTATE TEXT='For desktops, the system administrator should follow these steps: Reboot the system and run the F10 Diagnostics, Execute the RAM LONG TEST.'


DEFine MSGREcord MSGID='* SNMPTRAP: * * *232 * * 6 2006 *'
       MSGNODE=*
       DEScription='HP - Desktop Correctable Memory: OK'
       TYPE=MSG
DEFine MSGACTion NAME=(*,10)
       ACTION=sendkeep TEXT='HP - Desktop Correctable Memory: OK'
       SEVerity=S
       ATTRIB=default
       COLOR=green
DEFine MSGACTion NAME=(*,20)
       ACTION=ANNOTATE TEXT='Correctable memory error count is now below the threshold for the memory module. The appropriate Memory Module ECC Status has been set to OK.'

DEFine MSGREcord MSGID='* SNMPTRAP: * * *232 * * 6 2007 *'
       MSGNODE=*
       DEScription='HP - Desktop Memory Configuration Change'
       TYPE=MSG
DEFine MSGACTion NAME=(*,10)
       ACTION=sendkeep TEXT='HP - Desktop Memory Configuration has Changed'
       SEVerity=I
       ATTRIB=default
       COLOR=blue
DEFine MSGACTion NAME=(*,20)
       ACTION=ANNOTATE TEXT='A change in memory configuration has been detected on this system.  Note the name of the system issuing the alarm from the Alarm Detail window and verify a valid reason for the occurrence of a memory configuration change.'

DEFine MSGREcord MSGID='* SNMPTRAP: * * *232 * * 6 2011*'
       MSGNODE=*
       DEScription='HP - Battery has FAILED'
       TYPE=MSG
DEFine MSGACTion NAME=(*,10)
       ACTION=sendkeep TEXT='HP - Battery has failed'
       SEVerity=E
       ATTRIB=default
       COLOR=red

DEFine MSGREcord MSGID='* SNMPTRAP: * * *232 * * 6 2012*'
       MSGNODE=*
       DEScription='HP - Battery Charging DEGRADED'
       TYPE=MSG
DEFine MSGACTion NAME=(*,10)
       ACTION=sendkeep TEXT='HP - Battery Charging DEGRADED'
       SEVerity=W
       ATTRIB=default
       COLOR=orange
DEFine MSGACTion NAME=(*,20)
       ACTION=ANNOTATE TEXT='The portable battery charging capacity has degraded.  The battery can no longer be fully recharged.  If using multiple batteries, run the Power Conservation Utility to identify the battery location.'


DEFine MSGREcord MSGID='* SNMPTRAP: * * *232 * * 6 2013 *'
       MSGNODE=*
       DEScription='HP - Battery Calibration Error DEGRADED'
       TYPE=MSG
DEFine MSGACTion NAME=(*,10)
       ACTION=sendkeep TEXT='HP - Battery Calibration Error: The battery can not correctly indicate capacity'
       SEVerity=W
       ATTRIB=default
       COLOR=orange


DEFine MSGREcord MSGID='* SNMPTRAP: * * *232 * * 6 2014*'
       MSGNODE=*
       DEScription='HP - Desktop Correctable Memory: DEGRADED'
       TYPE=MSG
DEFine MSGACTion NAME=(*,10)
       ACTION=sendkeep TEXT='HP - Desktop Correctable Memory: DEGRADED'
       SEVerity=W
       ATTRIB=default
       COLOR=orange
DEFine MSGACTion NAME=(*,20)
       ACTION=ANNOTATE TEXT='Correctable memory error count has exceeded the threshold for the memory module. The appropriate Memory Module ECC Status has been set to degraded.'
DEFine MSGACTion NAME=(*,30)
       ACTION=ANNOTATE TEXT='For desktops, the system administrator should follow these steps: Reboot the system and run the F10 Diagnostics, Execute the RAM LONG TEST.'